Hot mix asphalt plant controls
ROVER &
ROVER LITE
Control the blend from one touchscreen. ROVER LITE handles aggregate feed, weighing, and asphalt metering. Choose ROVER if your mix also calls for an asphalt additive or mineral filler.
01 / Featured system
ROVER & ROVER LITE plant blending controls
ROVER and ROVER LITE use a Siemens SIMATIC S7-1200 PLC for blending control in new and retrofit hot mix asphalt plants.
ROVER
- Up to 4 aggregate feed bins
- 1 asphalt pump and meter
- 1 virgin aggregate weigh bridge
- 1 asphalt additive channel (% of asphalt)
- 1 mineral filler channel (gravimetric or volumetric)
ROVER LITE
- Up to 4 aggregate feed bins
- 1 asphalt pump and meter
- 1 virgin aggregate weigh bridge
Available as a complete console.
Product specifications
Aggregate feed bin control
- Feeder drives
- Control for up to 4 bin feeders with variable-frequency (VFD), eddy-current or DC drives.
- Start, stop and speed
- 24 V DC PLC start/stop control for VFDs, with 120 V AC plant connections through I/O isolation relays. Scaled 0–10 V speed reference corresponds to 0–100% speed.
- Speed feedback
- 1,200-pulse-per-revolution (PPR) encoder feedback through the PLC’s built-in high-speed counter.
- Operator display
- VFD status and speed settings, calibrated feed rate in tons per hour (TPH), maximum TPH entry for rate calculation, and recurring no-flow indication on the alarm screen.
Asphalt pump and meter control
- Pump drive
- Control for one asphalt pump with a VFD, eddy-current or DC drive. The PLC uses 24 V DC for VFD start/stop and spray/divert control and interfaces with the 120 V AC plant through I/O isolation relays.
- Speed and rate
- Scaled 0–10 V reference for 0–100% speed. The PLC’s built-in high-speed counter reads a 1,200 PPR encoder. The operator display shows drive status, speed settings and the calibrated rate in TPH, with a maximum TPH entry for rate calculation.
- Temperature
- Asphalt temperature compensation with a Type J thermocouple input. Operators can adjust input scaling and offset on the touchscreen.
- Calibration and alarms
- Touchscreen setup and calibration assistance. Calibration defaults are based on a Viking KK225 2-inch pump or equivalent. Operators can configure the recurring out-of-tolerance alarm.
Virgin aggregate weigh bridge control
- Weigh bridge inputs
- One weigh bridge with 0–10 V analog load-cell input and belt speed from a 1,200 PPR encoder through the PLC’s built-in high-speed counter. A load-cell signal conditioner, such as an Action Pak, is optional.
- Rate and moisture
- Calibrated rate calculation and TPH display use belt speed feedback. Moisture compensation uses one percentage entered on the touchscreen. Composite moisture calculation from individual aggregates is unavailable.
Asphalt additive and mineral filler control (ROVER only)
- Asphalt additive
- One additive channel. The PLC calculates the dose as a percentage of asphalt.
- Mineral filler
- One filler channel with gravimetric or volumetric control. Mineral filler feeds directly into the mixing drum, bypassing the aggregate weigh bridge.
- Drive control
- Both channels support VFD, eddy-current and DC drives. VFD start/stop uses 24 V DC PLC control with 120 V AC plant connections through I/O isolation relays. Scaled 0–10 V speed reference corresponds to 0–100% speed.
- Feedback and rate
- Both channels use 1,200 PPR encoder feedback through the PLC’s built-in high-speed counter. The touchscreen shows drive status, speed settings and calibrated rate in TPH, and accepts maximum TPH for rate calculation.
PLC software and operator controls
- Mix control
- Mix temperature uses a Type J thermocouple input with touchscreen scaling and offset. Travel time from the aggregate weigh bridge to the asphalt spray point is adjustable from 60 to 120 seconds. Production tracking ends at the spray point.
- Production overview
- Shows all enabled ingredients and key production values. Daily, period and long-term totalizers can be reset individually. Mix and asphalt temperature trends display in °F or °C.
- Operator settings
- English or Spanish, US or metric units, °F or °C, and operator display settings.
- Aggregate and asphalt settings
- Set aggregate maximum TPH, weigh bridge moisture, travel time to the asphalt spray point and no-flow alarm enablement. Asphalt settings cover maximum TPH and temperature scaling and offset. Calibration assistance is available for both.
- Diagnostics and alarm history
- Digital and analog input and output lists, PLC and touchscreen health, and system and process alarm history.
Siemens PLC and I/O racks
SIMATIC S7-1200 main rack · Both models
- Slot 1 · CPU 1214C
- Compact DC/DC/relay CPU, 14 digital inputs at 24 V DC, 10 relay outputs rated 2 A and 2 analog inputs at 0–10 V DC. Supply: 20.4–28.8 V DC. Program and data memory: 150 KB.
- Slot 1 · SB 1221 signal board
- 4 sourcing digital inputs, 24 V DC, 200 kHz.
- Slot 2 · SM 1221
- 8 digital inputs, 24 V DC, sink or source.
- Slot 3 · SM 1231
- 4 analog inputs: ±10 V, ±5 V, ±2.5 V, 0–20 mA or 4–20 mA. Resolution: 12 bits plus sign (13-bit ADC).
- Slots 4 and 5 · SM 1232
- Each module has 4 analog outputs: ±10 V at 14-bit resolution, or 0–20 mA or 4–20 mA at 13-bit resolution.
- Slot 6 · SM 1231 TC
- 4 analog thermocouple inputs.
- Slot 7 · PM1207 power module
- Stabilized supply: 120/230 V AC input, 24 V DC output at 2.5 A.
Second I/O rack · ROVER only
- Slot 1 · CPU 1211C
- Compact DC/DC/relay CPU, 6 digital inputs at 24 V DC, 4 relay outputs rated 2 A and 2 analog inputs at 0–10 V DC. Supply: 20.4–28.8 V DC. Program and data memory: 75 KB.
- Slot 1 · SB 1222 signal board
- 4 digital outputs, 24 V DC, 200 kHz.
PLC I/O isolation relays
ROVER and ROVER LITE use Phoenix Contact interposing relays to interface 120 V AC plant signals with 24 V DC PLC I/O. Isolation between the module input and switched contact helps reduce electrical noise coupling between the circuits.
- Plant input relay
- PLC-RSC-120UC/21 (2966197) handles 120 V AC plant input signals. The module’s nominal input rating is 120 V AC or 110 V DC.
- PLC output relay
- PLC-RSC-24DC/21 (2966171) accepts a 24 V DC command from the PLC and switches the plant-side circuit through an isolated contact.
- Mounting and service
- Both modules use screw terminals, one changeover contact (SPDT), and NS 35/7.5 DIN rail mounting. The plug-in electromechanical relay can be replaced separately from the PLC I/O module.
Siemens HMI display options
SIMATIC HMI Unified Comfort widescreen TFT panels support multi-touch or a wireless USB mouse and keyboard.
- MTP700 (NOMAD)
- 7.0 inches, 800 × 480 pixels.
- MTP1000
- 10.1 inches, 1280 × 800 pixels.
- MTP1500
- 15.6 inches, 1366 × 768 pixels.
Other SIMATIC HMI Unified Comfort panels are available.
Plant interfaces and equipment options
Plant interface hardware
- Ewon Cosy+ Ethernet
- VPN gateway for remote access to the PLC, HMI or other connected devices through Talk2m.
- Brainboxes SW-504
- Unmanaged industrial Ethernet switch, four 10/100 ports, DIN rail mounting and dual redundant 5–30 V DC inputs.
- ROVER cable set
- 25-foot cable set using LAPP KABEL and Belden cables.
Optional equipment
- Load-cell signal conditioner
- Optional. Listed suppliers: Allen-Bradley, Absolute Process Instruments and Omega Engineering.
- COSTA Industrial tach encoders
- Optional.
- Other listed options
- Cables, load cells and asphalt valve position limit switches. Ask about availability for your configuration.
02 / Other equipment
Equipment and service
- Liquid asphalt transfer equipment for ISO tanks
- Asphalt calibration tanks and scales
- Asphalt heating equipment and parts
- Pumps and motors
- Electrical controls and parts
- Installation and service
03 / Direct contact
Talk with Rick Costa
Run your plant specs by Rick before you order. His advice draws on more than 40 years in the industry.